| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Components of the YoSmart YoLink ecosystem through 2025-10-02 leverage unencrypted MQTT to communicate over the internet. An attacker with the ability to monitor network traffic could therefore obtain sensitive information or tamper with the traffic to control affected devices. This affects YoLink Hub 0382, YoLink Mobile Application 1.40.41, and YoLink MQTT Broker. NOTE: The vendor states that the vulnerability described (related to insecure transmission) only impacts the legacy mobile application logic, not the Hub hardware or firmware. The Hub functions solely as a pass-through (transparent gateway) for LoRa wireless data and does not inspect or process the application layer data. |
| YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission |
| Cleartext Storage of Sensitive Information in Memory vulnerability in ABB MConfig.This issue affects MConfig: through 1.4.9.21. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| Lack of sensitive data encryption in CapillaryScope v2.5.0 of Capillary io, which stores both the proxy credentials and the JWT session token in plain text within different registry keys on the Windows operating system. Any authenticated local user with read access to the registry can extract these sensitive values. |
| Cleartext Storage of Sensitive Information vulnerability in OpenText™ Vertica allows Retrieve Embedded Sensitive Data.
The vulnerability could read Vertica agent plaintext apikey.This issue affects Vertica versions: 23.X, 24.X, 25.X. |
| A flaw has been found in editso fuso up to 1.0.4-beta.7. This affects the function PenetrateRsaAndAesHandshake of the file src/net/penetrate/handshake/mod.rs. This manipulation of the argument priv_key causes inadequate encryption strength. Remote exploitation of the attack is possible. A high degree of complexity is needed for the attack. The exploitability is reported as difficult. |
| With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database. |
| An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device. |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. |
| The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings. |
| An issue was discovered in the method push.lite.avtech.com.AvtechLib.GetHttpsResponse in AVTECH EagleEyes Lite 2.0.0, the GetHttpsResponse method transmits sensitive information - including internal server URLs, account IDs, passwords, and device tokens - as plaintext query parameters over HTTPS |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection. |
| This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device. |
| EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage. |
| A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure. |