| A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
| Information Disclosure can occur in Hitek Software's Automize 10.x and 11.x passManager.jsd. Users have the Read attribute, which allows an attacker to recover the encrypted password to access the Password Manager. |
| hitek.jar in Hitek Software's Automize uses weak encryption when encrypting SSH/SFTP and Encryption profile passwords. This allows an attacker to retrieve the encrypted passwords from sshProfiles.jsd and encryptionProfiles.jsd and decrypt them to recover cleartext passwords. All 10.x up to and including 10.25 and all 11.x up to and including 11.14 are verified to be affected. |
| Information Disclosure can occur in encryptionProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for GPG Encryption profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14. |
| Information Disclosure can occur in sshProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for SSH/SFTP profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14. |
| An issue was discovered in certain Apple products. iOS before 10.1 is affected. The issue involves the "iTunes Backup" component, which improperly hashes passwords, making it easier to decrypt files. |
| An issue was discovered in certain Apple products. iOS before 10.2 is affected. macOS before 10.12.2 is affected. watchOS before 3.1.3 is affected. The issue involves the "Security" component, which makes it easier for attackers to bypass cryptographic protection mechanisms by leveraging use of the 3DES cipher. |
| xbcrypt in Percona XtraBackup before 2.3.6 and 2.4.x before 2.4.5 does not properly set the initialization vector (IV) for encryption, which makes it easier for context-dependent attackers to obtain sensitive information from encrypted backup files via a Chosen-Plaintext attack. NOTE: this vulnerability exists because of an incomplete fix for CVE-2013-6394. |
| IBM BigFix Compliance Analytics 1.9.79 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 123431. |
| An issue was discovered in sysPass 2.x before 2.1, in which an algorithm was never sufficiently reviewed by cryptographers. The fact that inc/SP/Core/Crypt.class is using the MCRYPT_RIJNDAEL_256() function (the 256-bit block version of Rijndael, not AES) instead of MCRYPT_RIJNDAEL_128 (real AES) could help an attacker to create unknown havoc in the remote system. |
| On the TP-Link TL-SG108E 1.0, admin network communications are RC4 encoded, even though RC4 is deprecated. This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| Huawei USG6300 V100R001C30SPC300 and USG6600 with software of V100R001C30SPC500,V100R001C30SPC600,V100R001C30SPC700,V100R001C30SPC800 have a weak algorithm vulnerability. Attackers may exploit the weak algorithm vulnerability to crack the cipher text and cause confidential information leaks on the transmission links. |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. |
| In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
|
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
| Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. |
| An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06. |
| Hills ComNav version 3002-19 suffers from a weak communication channel. Traffic across the local network for the configuration pages can be viewed by a malicious actor. The size of certain communications packets are predictable. This would allow an attacker to learn the state of the system if they can observe the traffic. This would be possible even if the traffic were encrypted, e.g., using WPA2, as the packet sizes would remain observable. The communication encryption scheme is theoretically sound, but is not strong enough for the level of protection required. |
| Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained. |
| Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic. |